The MSB2 and LSB both use the same firmware core with custom modifications to support the sensors and other subsystems specific to each platform. The goals of the firmware are:

  • Encapsulate all low level functions in easily accessible commands
    • Hides all startup/initialization routines
  • Provide a variable sampling schedule (with some constraints) that automatically handles powering off unused sensors
  • Provide commands for accessing calibration and other sensor metadata
  • Sample and send data via a hi-speed binary uart interface
    • Communicates with any embedded platform
    • Communicates with any desktop/laptop/handheld/cell phone with a available uart port


State Diagram

The system has two main states, the default wait state and the running state. The other states are used for setting up various components of the system. Once everything is working; however, the user simply enters the running state and begins recording data. In addition to the command states shown here available here several other commands are available (depending upon the hardware) which can be used to manipulate various parts of the system.

    System state diagram for communicating with the MSB firmware, the power point version is available here


Communication protocol

Communication with the MSB Firmware takes place over the first uart on the ATmega, at 921,600 baud, with an option of having flow control. You must only send one byte per timer interrupt! For example, if your INTERRUPT_COUNT is set to 5120 (512 Hz), you must wait at least 1/512th of a second between bytes.

Commands

    Commands are six-character sequences where '!' (hex 0x21) indicates the start of a command. The parser is reset by a '!', so if you make a mistake when sending a command, simply resend the command starting with a '!'. Some commands include their arguments as part of their five command bytes.
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 Command

    Note: '!' is a reserved character and may not be used as an argument for any command that includes its arguments in the command bytes.

LED Commands

    LED commands are special one-byte commands that turns the LEDs on and off. Two LED command formats exist: one to adjust the individual LEDs, and one to adjust both the individual LEDs and the tri-color LED. In both formats, a 0 bit for an LED turns it on, and a 1 bit turns it off.

    Individual LED command format

    Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
    0 0 0 0 Red Green Blue 1

    Individual and Tricolor LED command format

    Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
    1 Tri-color Blue Tri-color Green Tri-color Red Red Green Blue 1

Packet format (from the MSB Firmware)

    All MSB firmware responses will be sent back as packets that begin with 2 characters '#' followed by '|', then an identifier byte describing what the packet is and how it should be interpreted.
    Byte 0 Byte 1 Byte 3
    '#' 0x23 '|' 0x7C ID

Example Communication Sequence

    Here's an example of what a host computer would send to query the state of the LED and what it would receive from the MSB:

    Host sends: '!query' + 0x10 [query command + 0x10 to indicate a LED query]
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
    '!' 0x21 'q' 0x71 'u' 0x75 'e' 0x65 'r' 0x72 'y' 0x79 0x10

    MSB Firmware responds with: ['#|' start header + 0x10 to indicate a LED packet and 0x00 the current state of the LEDs

    Byte 0 Byte 1 Byte 2 Byte 3
    '#' 0x23 '|' 0x7C 0x10 0 0x00

Available Commands

Start Command

    This command begins sampling of the sensors and outputting the readings. May only be executed in the WAIT state.

    Host sends: '!start'
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 's' 0x73 't' 0x74 'a' 0x61 'r' 0x72 't' 0x74

Cease Command

    This command stops sampling of the sensors. May only be executed in the RUNNING state.

    Host sends: '!cease'
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 'c' 0x63 'e' 0x65 'a' 0x61 's' 0x73 'e' 0x65

Reset Command

    This command reinitializes the sensor board. May only be executed in the WAIT state.

    Host sends: '!reset'
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 'r' 0x72 'e' 0x65 's' 0x73 'e' 0x65 't' 0x74

Alter Schedule Command

    This command alters the sensor sampling schedule. May only be executed in the WAIT state.

    Host sends: '!alter' INTERRUPT_COUNT MIC_HZ ACCELEROMETER_HZ AMB_LIGHT_HZ BAROMETER_HZ COMPASS_HZ DALS_HZ HUMIDITY_HZ POWER MIC_GAIN
    All parameters except POWER and MIC_GAIN are 16-bit unsigned integers, sent in little-endian order. POWER and MIC_GAIN are 8-bit unsigned integers.
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9 Byte 10 Byte 11
    '!' 0x21 'a' 0x61 'l' 0x6c 't' 0x74 'e' 0x65 'r' 0x72 Interrupts Per 10 Secs Mic Hz Accelerometer Hz * 10
    Low-order High-order Low-Order High-Order Low-Order High-Order
    Byte 12 Byte 13 Byte 14 Byte 15 Byte 16 Byte 17 Byte 18 Byte 19 Byte 20 Byte 21 Byte 22 Byte 23
    Ambient Light Hz * 10 Barometer Hz * 10 Compass Hz * 10 DALS Hz * 10 Humidity Hz * 10 Power Control Mic Gain
    Low-order High-order Low-Order High-Order Low-Order High-Order Low-Order High-Order Low-Order High-Order

    Power Control Bits

    Certain sensors can be powered down in between samples. To enable this, set the appropriate bits in the power control byte. Note that due to the amount of time required to power up and down the sensors, the maximum sampling rate will be decreased for these sensors.

    Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
    0 0 0 0 0 Accel Compass DALS

    Microphone Gain

    This byte ranges from 0 to 255. 0 represents minimal gain, while 255 represents maximal gain. The gain may also be adjusted during sampling with the !gain command.

    Data Returned

    The MSB will verify that it can meet the desired schedule, and if not, will adjust it accordingly. In either case, the effective schedule will be returned over the serial port in the same format, except with "!alter" replaced with the MSB response bytes, with ID = 0x40.

Query Command

    This command returns various information about the state of the MSB. May only be executed in the WAIT state.

    Host sends: '!query' QUERY_ID
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
    '!' 0x21 'q' 0x71 'u' 0x75 'e' 0x65 'r' 0x72 'y' 0x79 Query ID

    Query Types

    ID Type
    0x40 Current Schedule
    0x20 Calibration Information
    0x10 LEDs State
    0x02 RTC Registers

USB Enable Command

    This command enables or disables the USB/Digital Compass power. May be executed in either the RUNNING or WAIT states.

    Host sends: '!usb-0' or '!usb-1'
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 'u' 0x75 's' 0x73 'b' 0x62 '-' 0x2d USB status ('0' or '1')

GPS Enable Command

    This command sets the state of the GPS Enable signal (Atmel_PA7). May be executed in either the RUNNING or WAIT states.

    Host sends: '!gps-0' or '!gps-1'
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 'g' 0x67 'p' 0x70 's' 0x73 '-' 0x2d GPS enable ('0' or '1')

Gain Command

    This command temporarily adjusts the gain while the sensors are being sampled. May only be executed in the RUNNING state.

    Host sends: '!gain' GAIN_VALUE
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 'g' 0x67 'a' 0x61 'i' 0x69 'n' 0x6e Gain

Write Command

    This writes the current schedule to the EEPROM to be used as the default schedule. May only be executed in the WAIT state.

    Host sends: '!write'
    Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5
    '!' 0x21 'w' 0x77 'r' 0x72 'i' 0x69 't' 0x74 'e' 0x65

Data Format